How much time does it require to take over the failure volume?
Description

In NUUO Crystal™ version 2.1, if there is volume failure, the system can automatically assign another volume to take over its recording job. But how much time does it require to take over the failure volume and start recording?

Instruction

The required time would be : Volume failure detect timeout(2 min)+ recording service restart time(15 sec) + Initialize all devices (2.5 sec per channel)+Repair DB 

For example, if NUUO Crystal™ with 32 channels recording volume failure and doesn't need DB repair, it will take about :

Volume failure detect timeout(2 min)+recording service restart time(15 sec)+Initialize all devices (2.5 sec x 32) = 3min 35 second
 
Customer Feedback
 